• Emailhsdq@188.com
  • Phone0571-82699352
  • 中文
Menu
  • Home
  • Products
    • Low-voltage distribution
    • Medium voltage distribution
    • Industrial control and protection
    • New energy
    • Complete sets of equipment
  • Download
    • Product sample
    • Manual of the modeling
    • Instruction book
    • Communication protocol
  • About Us
    • Brief introduction
    • “Hangshen” image
    • Technological innovation
    • Technical quality
    • Enterprise reputations
    • Enterprise culture
  • Contact Us

Products

Home>>HSC1 series AC contactor
  • Complete sets of equipment
    • Low Voltage Complete-set Switchgear Equipment
    • High Voltage Complete-set Switchgear Equipment
    • Prefabricated substation
  • Low-voltage distribution
    • surge protector
    • automatic transfer switch automatic switch
    • Intelligent instrument
    • Intelligent Type Air Circuit Breaker
    • Moulded Case Circuit Breaker
      • Thermal Magnetic Moulded Case Circuit Breaker
      • Intelligent Type Moulded Case Circuit Breaker
      • Residual Current Circuit Breaker
    • Switch Disconnector
    • End Terminal Appliances
  • Medium voltage distribution
    • Vacuum circuit breaker
  • Industrial control and protection
    • AC contactor
    • motor protector
    • control and protection switch
    • series thermal overload Relay
  • New energy
  • Email hsdq@188.com
    • Technical 0571-82699110
    • Sales 0571-82699109
    • Service 0571-82600655

HSC1 series AC contactor

Description

HSC1 series AC contactor is used in AC 50Hz, the main contact rated voltage to 690V, rated current 6.3A ~ 800A in the power system to connect and break circuit.It also can be combined with an appropriate electronic motor protector or a thermal overload relay to protect the electric circuit overload in the operation (running).  The combination of the two contactors and the mechanical interlock can be used for the control of reversible or reverse braking motors and dual power supply control.  products comply with IEC60947-4, GB14048.4 standards and obtain the national compulsory product certification “CCC” certificate.

DownloadHSC1 series AC contactor
  • Product Detail
  • Parameters

Installation site altitude not exceeding 2000m

The upper limit of ambient temperature is +55 DEG C, the lower limit is -25

The air relative humidity at the installation site shall be no more than 50% at the maximum temperature of +40 degrees celsius and can have a higher relative humidity at a lower temperature,for example air relative humidity can reach up to 90% under 20 degrees celsius.Special measures should be taken when changing temperature produces condensation.

Installation site pollution level of 3

The main circuit of the installation class is III, and the rest of the control and auxiliary circuits are Ⅱ

Installation method : Vertical installation, Inclination of the mounting surface ≤±22.5°

Table 1

Model HSC1-6.3 HSC1-9M HSC1-9 HSC1-12 HSC1-16 HSC1-25 HSC1-32 HSC1-40
Rated insulation voltage  Ui V 690
Rated heating Current  Ith A 16 20 30 45
Rated working Voltage Ue V 230    400    690
 

Rated working current   Ie  A

 

AC-3

230V 6.3 9 9 12 16 25 32 40
400V 6.3 9 9 12 16 25 32 40
690V 3.5 6.9 6.9 9.1 12.5 12.5 22.1 22.1
 

AC-4

230V 5 6.3 6.3 9 12 16 25 32
400V 5 6.3 6.3 9 12 16 25 32
690V 2.8 5 5 6.7 8.9 8.9 17.8 17.8
Control motor power

Kw  AC-3

230V 1.7 2.2 2.2 3.0 4.0 6.1 8.5 11
400V 3.0 4.0 4.0 5.5 7.5 11 15 18.5
690V 3.0 5.5 5.5 7.5 11 11 18.5 18.5
mechanical endurance Million times 1000
Long-life electrical        AC-3

Million times    AC-4

100

5

Million times     AC-3

次/h         AC-4

No load

800

250

7000

 

Operating

Rated voltage Us 36V    110V   127V   230V   400V
Start power consumption  VA 32 70 102 120
Holding power consumption  VA 5 8 12 15
Energy efficiency grade 3 3 3 3
 

Top mounted auxiliary contact

Model     Form

CA122     2NO2NC

CA131     3NO1NC

CA140     4NO

Model     Form

CA222     2NO2NC

CA231     3NO1NC

CA240     4NO

Side mounted auxiliary contact – Model:CA411

Form:1NO1NC

 

Delay module (Top mounting)

Delay on  

 

–

Model:TE1-3    TE1-30   TE1-180

Delay range:0.1~3s  1~30s   10~180s

Delay off Model:TE2-3    TE2-30   TE2-180Delay range

Delay range:0.1~3s  1~30s   10~180s

Communication interface module –
 Surge suppression module –
 Surge suppression module – ML1

continued Table 1

Model HSC1-50 HSC1-63 HSC1-75 HSC1-95 HSC1-110 HSC1-140 HSC1-170 HSC1-205
Rated insulation voltage  Ui V 690
Rated heating current Ith A 70 95 140 205
Rated heating current Ith A 230    400    690
 

Rated working current

Ie

A

 

AC-3

230V 50 63 75 95 110 140 170 205
400V 50 63 75 95 110 140 170 205
690V 34.6 34.6 61 61 110 118 170 170
 

AC-4

230V 40 50 63 75 90 110 140 170
400V 40 50 63 75 90 110 140 170
690V 25 25 52.8 52.8 60 95 100 122
Control motor

Power

Kw  AC-3

230V 15 18.5 22 22 37 45 55 64
400V 22 30 37 45 55 75 90 110
690V 30 30 55 55 75 110 156 156
mechanical endurance     Million times 1000
mechanical endurance     Million times       AC-3

Million times        AC-4

100

5

Million times     AC-3 times/h         AC-4

No load

800

250

7000

800

250

5000

750

250

5000

700

200

5000

500

130

5000

 

Operating coil

Rated voltage Us 36V    110V   127V   230V   400V
Start power consumption  VA 190 275 387 906
Holding power consumption VA 20.5 30 33 4.0
Energy efficiency grade 2 2 2 2
 

Top mounted auxiliary contact

Model    Form

CA322     2NO2NC

CA331     3NO1NC

CA340     4NO

 

–

Side mounted auxiliary contact Model:CA511  CA520  CA502   Form:1NO1NC   2NO   2NC
 

Delay module (Top mounting )

Delay on  

–

Model:TE1-3    TE1-30   TE1-180

Delay range:0.1~3s  1~30s   10~180s

 

–

Delay off Model:TE2-3    TE2-30   TE2-180

Delay range:0.1~3s  1~30s   10~180s

Communication interface module TX1
Surge suppression module RC1
 Mechanical locking module ML1 –

continued Table 1

Model HSC1-250 HSC1-300 HSC1-400 HSC1-475 HSC1-630 HSC1-800
Rated insulation voltage Ui V 690
Rated heating current Ith A 300 400 475 630 800
Rated working voltage  Ue V                   230    400    690
 

Rated working current

Ie

A

 

AC-3

230V 250 300 400 475 630 800
400V 250 300 400 475 630 800
690V 205 250 300 400 630 800
 

AC-4

230V 205 250 300 300 570 570
400V 205 250 300 270 520 520
690V 160 160 190 190 362 362
Control motor

power

Kw  AC-3

230V 78 93 125 145 191 250
400V 132 160 200 250 335 450
690V 190 235 275 375 573 750
mechanical endurance     Million times 600
Long-life electrical    AC-3

Million times         AC-4

60

5

Operating frequency     AC-3

次/h         AC-4

No load

700

200

3000

500

130

3000

500

150

2000

400

150

2000

500

150

1000

 

Operating coil

Million times Us 36V    110V   127V   230V   400V
Start power consumption

VA

906 620 1018
Holding

power consumption VA

4.0 11 14
Energy efficiency grade 2 2 2 –
Top mounted auxiliary contact                             –
Side mounted auxiliary contact Model:CA511  CA520  CA502   Form:1NO1NC   2NO   2NC
 

Delay module

(Top mounting)

Delay on  

 

–

Delay off
Communication interface module TX1
Surge suppression module RC1
Mechanical locking module –
notes:
  1. HSC1-6.3 ~ 12 also can provide the four poles
  2. Mechanical locking module does not separate supply and must be matched with the contactor. When not specified, auxiliary contacts with 1 open and 1 closed
  3. GB21518 suitable 《 AC contactor energy efficiency limit value and energy efficiency grade 》 for rated operating current 6A ~ 630A AC contactor
  4. The reversible AC contactor has the same parameters as the standard

Table 2

Table 2 HSC1-25C HSC1-40C HSC1-63C HSC1-95C
Rated insulation voltage Ui 690V
Rated heating current  Ith 30A 45A 70A 95A
Rated working voltage   Ue 230V   400V
Rated working current   Ie 230V 25 40 63 95
400V 25 40 63 95
AC-6b

Rated control capacity kvar

230V 10 15 25 35
400V 15 30 45 60
Surge suppression capability ≤20Ie
mechanical endurance        Million times 100
AC-6b Long-life electrical    Million times 10
Operating frequency          times/h 240 120
Operating coil characteristics and power consumption AC contactor with HSC1 serie
 

Auxiliary contact  ( Side loading )

Factory configuration:CA411    1只

Optional installation :CA411    1只

 

Factory configuration:CA511      1只

Optional installation  :CA511 or CA52 or             CA502     1只

Equipped with a fuse model RT16-50 RT16-63 RT16-125 RT16-160

Related Products

HSD1 series electronic motor protector
HSD1 series of electronic motor protector (hereinafter referred to as protector) is suitable for AC 50Hz, rated voltage to 400V, rated current 0.5A ~ 300A single AC asynchronous motor circuit…
More
HSD2 series electronic motor protector
HSD2 series intelligent motor protector (hereinafter referred to as protector) has protection function of overload,phase failure,unbalance,under load, grounding protection , stall ,blocking, starting overtime, temperature (PTC), over voltage, under voltage,…
More
HSJR1 series thermal overload Relay
The series thermal relay has three shell frame of 25A、36A、93A, current specification 1A~93A. A full range of thermal relay can be installed vertically. After installation, the slope does not exceed…
More
HSC2 series AC contactor
HSC2 series AC contactor (hereinafter referred to as the contactor) for AC 50Hz, voltage 400V, current to 95A, for long-distance making and breaking circuit and frequent starting and control of…
More
  • HangShen mobile website Latest news on mobile phone
  • HangShen wechat Scan with Wechat app
  • Products
    • Low-voltage distribution
    • Medium voltage distribution
    • Industrial control and protection
    • New energy
    • Complete sets of equipment
  • Download
    • Product sample
    • Manual of the modeling
    • Instruction book
    • Communication protocol
  • About Us
    • Brief introduction
    • “Hangshen” image
    • Technological innovation
    • Technical quality
    • Enterprise reputations
    • Enterprise culture
  • Contact Us
Copyright 2016© HangShen Electric All Rights Reserved. ICP14040535-3
Web Development by Anttoweb Web Design.
WordPress Image Lightbox Plugin